Zolfagharloo F, Nasr N, Tavakkol O, Momayezinejad M. Effect of Crown Dimensions on Stress Distribution in Implant Abutment Screw: A 3D Finite Element Analysis. J Res Dent Maxillofac Sci 2023; 8 (2) :119-127
URL: http://jrdms.dentaliau.ac.ir/article-1-400-fa.html
Effect of Crown Dimensions on Stress Distribution in Implant Abutment Screw: A 3D Finite Element Analysis. . 1402; 8 (2) :119-127

URL: http://jrdms.dentaliau.ac.ir/article-1-400-fa.html


چکیده:   (1292 مشاهده)
Background and Aim:   This study assessed the effect of crown dimensions on stress distribution in the abutment screw upon loading using three-dimensional (3D) finite element analysis (FEA).
Materials and Methods: Eighteen finite element models were designed using Mimics, 3D-Matic, Catia, and ANSYS software programs. Implant models were designed with 8.5-, 10- and 11.5-mm fixture heights, three different vertical cantilever heights of 8, 10, and 12 mm, and two horizontal cantilever lengths of 7 and 14 mm for the mandibular first and second molars. The interaction effect of of 120 N and 20 N loads on the implant and implant crown at the site of first molar, and the interaction effect of 150 N and 25 N loads on the cantilever at the site of second molar were analyzed.
Results: By an increase in horizontal cantilever length, stress in the abutment screw, abutment, and fixture increased in all models. Stress decreased in the abutment screw and increased in the abutment and fixture by an increase in vertical cantilever. Minimum screw stress was recorded in implants with 8.5 mm fixture height, 7 mm horizontal cantilever, and 12 mm vertical cantilever. Maximum screw stress was noted in implants with 11.5 mm fixture height, 14 mm horizontal cantilever, and 8 mm vertical cantilever.
Conclusion: According to FEA, increasing the horizontal and vertical cantilever length may result in an increased risk of screw loosening and fatigue fracture due to increased stress values in the screw or in other components (abutment and fixture), respectively.
متن کامل [PDF 1056 kb]   (915 دریافت)    
نوع مطالعه: Original article | موضوع مقاله: Prosthodontics

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Journal of Research in Dental and Maxillofacial Sciences

Designed & Developed by : Yektaweb