دوره 4، شماره 4 - ( 7-1398 )                   جلد 4 شماره 4 صفحات 27-23 | برگشت به فهرست نسخه ها


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Neshandar M, Baloch F, Mousavisedighi S, Bitaraf T. Evaluation of the Effect of Two Types of Autopolymerizing Acrylic Resin Splints on Dimensional Accuracy in Open Tray Impression Technique. J Res Dent Maxillofac Sci 2019; 4 (4) :23-27
URL: http://jrdms.dentaliau.ac.ir/article-1-250-fa.html
Evaluation of the Effect of Two Types of Autopolymerizing Acrylic Resin Splints on Dimensional Accuracy in Open Tray Impression Technique. . 1398; 4 (4) :23-27

URL: http://jrdms.dentaliau.ac.ir/article-1-250-fa.html


چکیده:   (3160 مشاهده)

Background and Aim: One of the main goals in the fabrication of an implant-supported prosthesis is to build a superstructure with passive fitness. If this fails, it will lead to the failure of the implant components. This study aimed to investigate the effect of Duralay and Pattern Resin splinting materials on dimensional accuracy in the open tray impression technique.
Materials and Methods: An edentulous acrylic model was developed. In the lateral teeth area, two implants (CMI, Neobiotech Co.) were placed perpendicularly and parallel to each other. The implants were cemented with cyanoacrylate. Pattern Resin (n=10) and Duralay (n=10) were used to splint the impression copings, and the impression was taken using the open tray technique. The main casts (20 pieces) were made with Vel-Mix type IV plaster using a vacuum mixer. The dimensional changes of each group were measured using a multi-axial coordinator. T-test was used to analyze the data.
Results: The mean dimensional changes of implant position transfer at the x-axis were 5.04±0.37 μm for Duralay and 5.58±0.13 μm for Pattern Resin. The mean dimensional changes of implant position transfer at the y-axis were 7.01±0.49 µm for Duralay and 6.78±0.15 µm for Pattern Resin. The mean dimensional changes of implant position transfer at the z-axis were 7.62±0.71 µm for Duralay and 6.86±0.12 µm for Pattern Resin. T-test showed that the difference between the two groups was not statistically significant (P>0.05).
Conclusion: According to the results, Duralay and Pattern Resin were not significantly different regarding dimensional changes in the open tray impression technique.

متن کامل [PDF 233 kb]   (1849 دریافت)    
نوع مطالعه: Original article | موضوع مقاله: Dental implant

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Journal of Research in Dental and Maxillofacial Sciences

Designed & Developed by : Yektaweb