Volume 6, Issue 2 (3-2021)                   J Res Dent Maxillofac Sci 2021, 6(2): 36-50 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Eskandarion S, Neshandar M, Rokhshad R. Classifications and Properties of Materials for Chairside Computer-Aided Design/Computer-Aided Manufacturing Dentistry: A Review. J Res Dent Maxillofac Sci 2021; 6 (2) :36-50
URL: http://jrdms.dentaliau.ac.ir/article-1-298-en.html
1- Dental Material research center, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
2- Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
3- Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran , Rat_shad@yahoo.com
Full-Text [PDF 515 kb]   (2374 Downloads)     |   Abstract (HTML)  (2953 Views)
Full-Text:   (2036 Views)
Abstract
Background and Aim: Chairside computer-aided design/computer-aided manufacturing (CAD/CAM) systems have become considerably more accurate, reliable, efficient, fast, and prevalent since 1985 when CEREC was introduced. The inceptive restorative material option for chairside CAD/CAM restorations was limited to ceramic blocks. Today, restorative material options have been multiplied and include metal alloys, ceramics, oxide ceramics, resins, and resin-matrix ceramics (RMC). This study aimed at making an overview of chairside CAD/CAM system materials and classifications.
Materials and Methods: An electronic search of the literature was carried out mainly through PubMed, ScienceDirect, Cochrane Library, and Google databases. The search aimed at collecting all the relevant English articles from 1965 to 2020.
Results: The analysis of the bond strength, fatigue resistance, flexural strength, elastic constants, microstructural characterization, accuracy, and clinical success of the materials showed variable outcomes. The marginal adaptation of resin ceramics has been reported to be comparable to that of lithium disilicate. It has been reported that the chairside CAD/CAM system using intraoral scanning is at least as accurate as the conventional method.
Conclusion: Chairside CAD/CAM restorations are fast, reliable, predictable, effective, patient-friendly, and cost-effective treatment options. Design software and intraoral scanners have made the treatment procedure simple. Chairside individualization of dental restorations could help improve patient satisfaction. However, considering the limited long-term clinical data, future studies need to address the long-term clinical performance of chairside CAD/CAM materials.
Keywords: Ceramics, Computer-Aided Design, Surface Properties, Treatment Outcome


Introduction
The computer-aided design (CAD)/computer-aided manufacturing (CAM) technology has been improving since 1985 when the CEREC system introduced the first chairside CAD/CAM. (1,2) Numerous chairside CAD/CAM systems are available in the market, including Planmeca (Planscan/Planmill-D4D Technologies, Richardson, TX, USA), Carestream CS solutions (Carestream Dental, Atlanta, GA, USA), and Fast scan (Glidewell, Newport Beach, CA, USA). (3) A large number of new CAD/CAM materials are available in the market, including Dentsply, Ivoclar-Vivadent, VITA Zahnfabrik, and Lava Ultimate (3M) products. (2,4,5) The conventional methods have been error-prone, complex, technique sensitive, time-consuming, and unpredictable. (6,7) On the other hand, CAD/CAM systems have become considerably more accurate, efficient, and less expensive and allow the restoration to be manufactured in a single appointment. (6-9)
CAD/CAM systems are divided into labside CAD/CAM system and chairside CAD/CAM system. In the labside CAD/CAM system, conventional impressions are taken, and then, the stone cast is scanned by an extraoral laboratory scanner, and the prosthesis is designed by the CAD software and then manufactured. With the chairside CAD/CAM system, all the manufacturing steps are done in the dental office, and all the components are in the dental office. (10)
CAD/CAM restorations are commonly fabricated in dental laboratories. There are different software programs for clinical and laboratory CAD/CAM. (11) Chairside CAD/CAM technology has some advantages such as easy and selective repeatability, speed, elimination of transport and delivery fees, easy archivability, material saving, patient satisfaction, true color display for dental and gingival visualization. However, it has some disadvantages such as learning curve, cost, sensitive scanning strategy, software error, and dry working field while scanning. (3)
Chairside CAD/CAM restorative materials have been studied for over 30 years. Dental restorative materials are now produced as blocks (cuboid) or blank (disc) and can be cut to a customized shape and size using wet grinding. (4,7,12) Dental ceramics were the first restorative materials for chairside CAD/CAM. Resin composites are the most commonly used materials in restorative dentistry and prosthodontics. (6,7,9,13)
Restorative chairside options now include polymethyl methacrylate (PMMA)-based materials, composites resins, resin-based ceramics, hybrid ceramics, silicate ceramics, feldspathic ceramics, traditional feldspathic ceramics, leucite-reinforced glass-ceramics, lithium silicate ceramics, lithium disilicate ceramics, zirconia-reinforced lithium silicate ceramics, oxide ceramics, zirconium dioxide ceramics, polycrystalline ceramics, and nanoceramics. (14)
Hybrid ceramics (a mixture of resin and ceramic) are a new category of chairside CAD/CAM materials.
Polymer-containing CAD/CAM materials have shown smoother crowns and less chipping at the margins after milling. (15) It is clear that the material’s microstructure and crystalline phase influence the clinical performance, mechanical properties, and aesthetics. (2,9)
The indications for chairside CAD/CAM materials include anterior teeth inlays, onlays, veneers, and posterior crowns. “Polymer-infiltrated ceramic-network (PICN)” and high-performance polymers (HPP) are groups of hybrid materials with 3M and Vita being the first introducers. (6,9,13) The advantages of nanoceramics compared to conventional blocks include superior mechanical properties, better machinability, and smoother milled margins. (16,17)
The improvement of intraoral scanners, design software, three-dimensional (3D) printing, and materials' quality and nature has led us to user-friendly multiple options. Chairside CAD/CAM procedure allows doing all treatment steps, from preparation to prosthesis fabrication, in the dental office. (10)
This study aimed at making an overview of chairside CAD/CAM materials and classifications to choose the best chairside material in treatment planning. In this review, we evaluate the indications and properties of these materials, including the bond strength, fatigue resistance, flexural strength, elastic constants, microstructural characterization, accuracy, and optical and clinical outcomes. 


Materials and Methods

An electronic search of the literature was done mainly through PubMed, ScienceDirect, Cochrane Library, and Google Scholar databases using the following keywords: "CAD/CAM" and “chairside" and “CAD/CAM" or "nano" or "ceramic" or "dental material" or "digital dentistry" or "resin”. The search aimed at collecting all the relevant English articles from 1965 to 2020. Fifty-seven articles were selected. The selection criteria are explained in the algorithm of the selection method in Figure 1. Recent studies on chairside CAD/CAM materials are mentioned in Table 1.
Figure 1. Algorithm of the article selection method
Table 1: Recent studies on chairside CAD/CAM materials


 
Results

Chairside CAD/CAM materials can be divided into metal alloys, ceramics, resin, and resin-matrix ceramics. There are several brands available for these materials. The indications and the brands of chairside CAD/CAM materials are mentioned in Table 2.
Classification:           
1-Metal alloys:
Chrome-cobalt and titanium are available metal blocks in the market. They can be used to fabricate a framework for crowns, fixed partial dentures, and metal ceramics. Titanium blocks can be milled to produce custom-made abutments. However, the lack of aesthetics is their disadvantage. (14) Nowadays, Sintron and Dentsply (Crypton) are available in the market.
2-Ceramics:
There are many classifications for ceramics. Feldspathic, Leucite-reinforced, lithium disilicate reinforced, zirconium oxide, and lithium silicate-reinforced are direct CAD/CAM glass-ceramics. Ceramic restorations have advantages such as excellent aesthetics, favorable milling properties and wear resistance, biocompatibility, and color stability. Their disadvantages include the need for more tooth preparation, brittleness, and wear of the opposing tooth. (11,41)
2-1-Glass-ceramics (silica-based):
Feldspathic: Feldspathic ceramics have two crystallization patterns as a sodium-potassium aluminum silicate peak and potassium-sodium aluminum silicate peak. (2) Due to their high aesthetic properties, they could be used for crowns, partial crowns, and veneers. There are types of blocks for aesthetic anterior restoration consisting of one block with a dentin core and enamel surrounding it. They have been popular for their indication in full-coverage crowns. This restoration could be finished by mechanical polishing and glazing. VITABLOCS Mark II (VITA Zahnfabrik) and CEREC Blocs (Dentsply Sirona) are available blocks in the market. (11)
Fages and colleagues have reported a 98.66% survival rate probability for reinforced feldspathic ceramics for 7 years of clinical service. (42) The long-term survival rate is well documented for CAD/CAM fabricated glass-ceramic restorations as inlays, onlays, and crowns. (2)
2-2-Leucite-reinforced:
These are formed in the glass state, which is later heat-treated. Leucite etches faster than glass-based ceramics and is very homogeneous. IPS Empress CAD (Ivoclar Vivadent) was the first type introduced. (14) Empress CAD (Ivoclar Vivadent) shows a low flexural strength (185MPa) but a high Weibull modulus (16.10), according to the manufacturer.
Feldspathic and leucite-reinforced ceramics have great translucency. In optical properties, they are superior to other dental ceramics while they cannot be used for hiding metal-inlay cores. In addition, they are not adequate against occlusal stress. (11,14)
2-3-Lithium silicate/disilicate ceramics:
Lithium silicate has been indicated for monolithic crowns, inlays, and onlays. Their biaxial flexural strength (407 MPa) has made them the strongest silica-based ceramics. (11)
IPS e.max CAD (Ivoclar Vivadent) and lithium silicate/phosphate glass-ceramics have been recently introduced to the market. CAD/CAM LDS crowns show satisfactory clinical outcomes for chairside manufacturing. (2)
Lithium disilicate has favorable translucency and shade variety. It is indicated for implant restoration and anterior/posterior fixed dental prostheses (FDPs). IPS e.max CAD (Ivoclar Vivadent) is the available block in the market.
Aziz and colleagues reported no chipping or fracture in a 4-year clinical study. Lithium disilicate glass-ceramic crowns exhibited a high survival rate (95%). In addition, patients and clinicians rated the aesthetics as excellent. (43)
2-4-Oxide ceramics:
They have been used for their excellent mechanical properties (high flexural strength against masticatory forces). They can be indicated for full coverage restorations. They should be air-particle abraded by alumina or silica-coated alumina. (2) The new generation of zirconia has represented great light transmission but the first generation had limited translucency. There are high translucent blocks available in the market, such as CEREC Zirconia (Dentsply Sirona), Katana Zirconia Block (Kuraray Noritake Dental Inc.), and VITA YZ (VITA Zahnfabrik).
Leeson has reported that monolithic crowns can be milled with a highly polished appearance and excellent surface quality. (44)
Fast sintering chairside CAD/CAM zirconia blocks (3M Chairside zirconia and Katana STML) have minimized the sintering time from the traditional 8 hours to 20 minutes. (45)
3-Resin:
Resin-based materials have several advantages such as easy polishing and high fatigue resistance. (11) There are four types available in the market: PMMA, resin-composites, nanoceramics, and PICN (polymer-infiltrated ceramic network).
3-1-PMMA (polymethyl methacrylate)
The thermoplastic polymer is transparent. PMMA decreases the milling time. Also, lack of fillers leads to low mechanical strength. These are used for temporary restorations (veneers, crowns, bridges, and inlays/onlays) from 6 months to one year. (14) Cerec guide bloc/inCoris PMMA (Dentsply Sirona), Telio CAD (Ivoclar Vivadent), and VITA CAD-Temp mono colors/multi colors Blocks (VITA Zahnfabrik) are examples of available PMMA blocks in the market. (11)
3-2-Resin composites:
They are composed of a monomer matrix resin with fillers. They are easy to use and have great fatigue resistance. (14) The polymerization of composite resins is never complete. Paradigm MZ100 (3M ESPE), Tetric CAD (Ivoclar Vivadent), and CAD Temp mono/multicolor (Vita) blocks are available for chairside CAD/CAM for temporary restorations for up to 3 years with greater mechanical resistance than PMMA. They could be used for veneers, inlay/onlay, and anterior/posterior crowns and bridges. (2,5) It has been reported that chairside light-curing CAD/CAM resin-based composites are practicable and can be recommended for both experienced and inexperienced users. (46)
3-3-Nanoceramics:
They have fillers smaller than 100nm. They have characteristics similar to the natural teeth in terms of flexure, compression, and abrasion. Their bonding ability is excellent but their optical properties are medium. They are indicated for anterior/posterior single crowns and bridges (bridges with small extent). Ultimate (Lava) and Cerasmart (GC) are examples of available blocks in the market. (2,4,14,47). Note that these are new materials, and their biocompatibility is still questionable due to their monomer release.
3-4-High-performance polymers (HPP)
These are a group of hybrid materials. HPPs are heavily nanocomposite filled and polymerized under high pressure and temperature. They had been reported better machinability, higher flexural strength, modulus of resilience, and smoother milled margins in comparison to ceramics. (6,16) This material presents very good biocompatibility, a high temperature resistance, chemical inertness, good mechanical properties, good polishability, low plaque attachment, and good bond strength with veneering composites and cements. PEEK has a low modulus of elasticity in comparison to zirconium oxide and metal alloys. PEEK provides a reduction of stresses transferred to dental structures. Although PEEK is frequently used in dental clinical practice, only a few studies are available on the application of this material to digital dentistry. (48-52)
4-Resin-matrix ceramics (RMC):
These materials have two phases of polymer and ceramic with different structures. They are categorized as follows:
4-1-Resin-based ceramics:
They have the combined advantages of polymers and ceramics, which result in superior aesthetics and strength. They can be glazed. Cerasmart (GC), Grandio Blocs (VOCO), LAVA Ultimate (3M ESPE), and KATANA AVENCIA block (Kuraray Noritake Dental, Inc.) are available blocks in the market. (2,11)
4-2-Hybrid ceramics:
These could be milled in their ultimate form and allow quicker manufacturing. The IPN (ceramic-based resin interpenetrating) is composed of a feldspathic ceramic and acrylic polymer. (6) Hybrid ceramic chairside blocks have shown better machinability and smoother milled margins. They are available as VITA ENAMIC (VITA Zahnfabrik) in the market. (2)
4-3-PICN (polymer-infiltrated ceramic network):
The PICN combines the properties of polymers and ceramics. VITA Enamic is available in the market. This material has similar abrasion, high flexural strength, and elasticity near to dentin with high bonding ability, although its optical properties are medium, and there is a lack of shade range. (14) The PICN could be indicated for veneers, inlays/onlays, and anterior/posterior single crowns. It has been reported that the PICN has better wear resistance compared to composite resins. (2,5)

Table 2. Examples of chairside CAD/CAM materials
Figure2:Examples of In Lab and chairside CAD-CAM materials.


Digital workflow:
CAD/CAM procedures consist of extraoral scanning of a stone cast or intraoral scanning, software that processes the stereolithography (STL) file and designs the restoration, and a fabrication system (subtractive or additive system). The STL file can be transferred to the laboratory. There are other file formats as PLY, DCM, and UDX. (11) This time-efficient process allows single appointment treatment. There are several CAD/CAM software programs available in the market, such as 3Shape Dental system, FreeForm, Exocad, Polywork, Dental wings (DWOS), and Digistell. Not all milling machines are able to mill and grind all types of restorative materials. There are millable materials as wax, metals, PMMA, hybrid ceramics, composite resins, high-performance polymers, polycrystalline ceramics, and resin-based ceramics. Additive manufacturing (3D printing) has been used for the fabrication of surgical guides, temporary restorations, occlusal splints, bite guards, scaffolds, and orthodontic appliances. Also, composites, metals, resins, and ceramics can be indicated for 3D printing. (45) It should be considered that material selection depends on the type of milling machine. Not all milling machines allow both dry milling and wet milling. Zirconia blocks should be dry milled but silica-based zirconia should be wet-milled. (11) There are different chairside CAD/CAM systems available in the market. Zaruba and Mehl have listed these systems as follows: CS 3500, CS 3600, CS 3000 (Carestream Dental, Rochester, NY, USA), Cerec Omnicam, Cerec MC, X, XL (Dentsply Sirona, York, PA, USA), DWIO, DWLM (Dental Wings, Montreal, Canada), myCrown Scan, myCrown Mill (Fona Dental, Bratislava, Slovakia), PlanScan, Emerald, PlanMill (Planmeca, Helsinki, Finland), IntraScan, Inhouse5x wet, and dry (Zfx, Dachau, Germany). Also, Chairside cooperation partners, such as Trios 3 Wireless (3Shape, Copenhagen, Denmark), PrograMill One (Ivoclar Vivadent, Schaan, Liechtenstein), Lyra Mill (Lyra, Paris, France), and CARES® C series (Straumann, Basel, Switzerland). (3)   
An increasing number of CAD/CAM materials and systems are now accessible. As a result, choosing the best chairside CAD/CAM material for each situation has become more challenging. (2) Chairside CAD/CAM systems use an intraoral scanner, software, and subtractive or additive manufacturing. (10)
Resin composites have shown a lower modulus of elasticity in comparison to ceramics. The flexural strengths after glazing of lithium disilicate (360±60MPa) and ZLS (370MPa) were reported to be in a similar range, whereas polished ZLS ceramics feature higher translucency. ZLS ceramics consist of a glass matrix with 10% dissolved zirconia. (53) Matzinger et al reported that ceramics had the lowest wear, followed by resin-infiltrated materials and resin composites. (53)
Al-Harbi and colleagues conducted an in-vitro study to evaluate the flexural strength, surface roughness, and surface hardness of resin nanoceramics (LAVA Ultimate) and leucite-reinforced VITA block mark II. The three aging processes included mechanical cycling (80 N), thermal cycling, and water. After aging, the surface roughness of nanoceramics was found to be comparable to that of leucite. They reported that leucite had higher surface hardness, and nanoceramics displayed higher flexural strength and surface roughness. (7)
Bankoğlu Güngör and Karakoca Nemli have evaluated the fracture resistance of chairside CAD/CAM monolithic ceramic and veneered zirconia molar crowns after thermomechanical aging and reported that the highest fracture resistance was observed for yttria-stabilized zirconia crowns followed by lithium disilicate. (54)
Wendler and colleagues examined the elastic constants, microstructural characterization, cyclic fatigue, lifetime, and flexural strength of polycrystalline zirconia, including e.max ZirCAD (Ivoclar Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar Vivadent), glass-ceramics (e.max CAD, Ivoclar Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) and hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE). They reported the strength of Vitablocs Mark II and e.max ZirCAD to be 110.9 MPa and 1303.21 MPa, respectively. The Young's modulus was reported to be 10.9 for Lava Ultimate and 201.4 for e.max ZirCAD. The Poisson’s ratio was reported to be 0.173 for Empress CAD and 0.47 for Lava Ultimate. More crack growths under cyclic loading were observed in lithium-based glass-ceramics and Vitablocs Mark II in comparison to other brands. (5,12,34)
Furtado de Mendonca et al conducted an in-vitro study to examine the microstructure, elastic modulus, fracture strength, and microhardness of lithium disilicate (IPS e.max, CAD), zirconia reinforced lithium silicate (VITA Suprinity), hybrid high-performance polymer (HPP) composite resin (GC Cerasmart), and hybrid polymer-infiltrated ceramic network (VITA Enamic) in the full crown of mandibular first molars. They reported that chairside materials are suitable for posterior full crown restorations. Hybrid materials exhibited lower hardness and stiffness compared to glass-ceramics. Chippings were more common in hybrid materials. (6)
Gul and Altınok-Uygun assessed the repair bond strength of nanohybrid resin composite blocks (Lava Ultimate, Cerasmart, and Vitablocs Mark II). They described that the lowest values were observed in the Vitablocs Mark II group (P<0.05). The Cimara System, Porcelain Repair, and Clearfil Repair showed significantly higher bond strength compared to other systems. They concluded that resin nanoceramics are more successful in intraoral repair applications. (22)
Bahadır and Bayraktar assessed the color stability and microtensile bond strength of Lava Ultimate, Vita Enamic, and nanofill composite resin. They reported the highest value (20.818 MPa) for non-thermocycled, bur-ground, silane-applied Vita Enamic. They stated that composite resin specimens showed more staining than the blocks (P<0.05). The authors recommended the use of silane in the repair process. (29)
Sismanoglu et al evaluated the reparability of Brilliant Crios, Lava Ultimate, Shofu Block HC, and Vita Enamic blocks. They reported the highest mean bond strength for Vita Enamic. (35)
According to Matzinger and colleagues, ceramics exhibited lower mean wear compared to resin composites. They evaluated different polishing procedures on labside and chairside resin-based composites, resin infiltrated ceramics, zirconia-reinforced lithium silicate, and lithium disilicate glass-ceramics. They found no significant differences in the roughness after labside and chairside polishing. The difference in the results may be explained by different filler compositions, material properties, and topography. (53)
High-density materials, such as ceramics based on lithium disilicate or feldspar, have shown the best color stability. (28) Crystalized glass-ceramics (CD/E-max) and Vita Mark II have shown the highest and lowest fracture toughness, respectively.
Fasbinder and colleagues reported that adhesive retention with total-etch or self-etch cementation resulted in similar clinical outcomes. Resilient ceramic onlays had a lower incidence of fracture than leucite-reinforced ceramic onlays, nanoceramics, and glass-ceramics. (4) Gul and Altınok-Uygun reported that Cimara, Porcelain Repair, and Clearfil Repair systems significantly increased the bond strength of nanohybrid resin composite for CAD/CAM blocks. (22)
Gasparik and colleagues showed that lithium disilicate or feldspar-based ceramics are highly dense materials with superior color stability. Hybrid ceramics showed color differences below the perceptible threshold. Composite-based materials showed lower color stability for their increased organic matrix. (28) Kanat-Ertürk reported that glazing rendered higher color stability than mechanical polishing, external staining, and glaze surface finishing. Polishing pastes decreased discoloration. (27)
Zirconia showed less volumetric loss than lithium disilicate and leucite. (36) Dursun and colleagues concluded that chairside CAD/CAM restorations are minimally invasive treatment options with high strength, biocompatibility, and aesthetics. They cause no gingival trauma and are easy to execute with a high patient satisfaction rate. (55) 
Fages et al have concluded that reinforced feldspathic ceramics have a very respectable clinical outcome in endocrowns. (42)
Nejatidanesh and colleagues have reported that chairside CAD/CAM ceramic laminate veneers (Empress CAD and e.max) were clinically successful with a mean survival rate of 99.0% and success rate of 96.4% after 5 years. (56) However, Magne et al have reported that posterior veneers made of composite resin (Paradigm MZ100) had significantly higher fatigue resistance (P<0.002) compared to IPS Empress CAD and IPS e.max CAD. (57)
Ahn and colleagues compared chairside CAD/CAM and labside CAD/CAM and reported that both CAD/CAM systems showed a proper fit that could be used clinically. (10)
Overall, heat-pressed lithium disilicate restorations have a better marginal fit in comparison to other CAD/CAM restorations. (45)
Chairside procedures have improved patient satisfaction by reducing the cost, clinical procedures, number of appointments, and treatment time. Intraoral scanning has simplified the treatment for patients with limited mouth opening or strong gag reflex. It has been reported that the chairside CAD/CAM system using intraoral scanning is at least as accurate as the conventional method. (3)
Currently, the digital approach is being implemented worldwide. It has emerged into a patient/clinician-friendly procedure. It should be considered that milling machines and 3D printers have become smaller. In addition, there are several updated design software programs. Many modern laboratory materials can be also fabricated using the chairside procedure. Clinicians should choose the chairside materials according to their work habits and material properties.


Conclusion

Based on the findings of this study, the following conclusions were drawn:
1) Chairside CAD/CAM restorations are fast, reliable, predictable, effective, patient-friendly, and cost-effective treatment options. Design software and intraoral scanners have made the treatment procedure simple. Chairside individualization of dental restorations could help improve patient satisfaction.
2) Different blocks are available in the market that allow the fabrication of all types of restorations and prosthetic reconstruction. However, there is no material for universal applications with ideal clinical outcomes and properties.
3) There are limited long-term clinical data and clinical experience on modern materials. Hence, future studies need to address the long-term clinical performance of chairside CAD/CAM materials.
Type of Study: Review article | Subject: Oral medicine

References
1. Emery RW, Merritt SA, Lank K, Gibbs JD. Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation. J Oral Implantol. 2016 Oct;42(5):399-405. [DOI:10.1563/aaid-joi-D-16-00025] [PMID]
2. Al Yafi F, Camenisch B, Al-Sabbagh M. Is Digital Guided Implant Surgery Accurate and Reliable? Dent Clin North Am. 2019 Jul;63(3):381-97. [DOI:10.1016/j.cden.2019.02.006] [PMID]
3. Deeb GR, Allen RK, Hall VP, Whitley D 3rd, Laskin DM, Bencharit S. How Accurate Are Implant Surgical Guides Produced With Desktop Stereolithographic 3-Dimentional Printers? J Oral Maxillofac Surg. 2017 Dec;75(12):2559.e1-2559.e8. [DOI:10.1016/j.joms.2017.08.001] [PMID]
4. Unsal GS, Turkyilmaz I, Lakhia S. Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review. J Clin Exp Dent. 2020 Apr 1;12(4):e409-e417. [DOI:10.4317/jced.55871] [PMID] [PMCID]
5. Sun TM, Lan TH, Pan CY, Lee HE. Dental implant navigation system guide the surgery future. Kaohsiung J Med Sci. 2018 Jan;34(1):56-64. [DOI:10.1016/j.kjms.2017.08.011] [PMID]
6. Bencharit S, Staffen A, Yeung M, Whitley D 3rd, Laskin DM, Deeb GR. In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery. J Oral Maxillofac Surg. 2018 Jul;76(7):1431-1439. [DOI:10.1016/j.joms.2018.02.010] [PMID]
7. Block MS, Emery RW. Static or Dynamic Navigation for Implant Placement-Choosing the Method of Guidance. J Oral Maxillofac Surg. 2016 Feb;74(2):269-77. [DOI:10.1016/j.joms.2015.09.022] [PMID]
8. Stefanelli LV, Mandelaris GA, Franchina A, Pranno N, Pagliarulo M, Cera F, et al. Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series. Int J Environ Res Public Health. 2020;17(14):5038. [DOI:10.3390/ijerph17145038] [PMID] [PMCID]
9. Zhou W, Liu Z, Song L, Kuo CL, Shafer DM. Clinical Factors Affecting the Accuracy of Guided Implant Surgery-A Systematic Review and Meta-analysis. J Evid Based Dent Pract. 2018 Mar;18(1):28-40. [DOI:10.1016/j.jebdp.2017.07.007] [PMID]
10. Mora MA, Chenin DL, Arce RM. Software tools and surgical guides in dental-implant-guided surgery. Dent Clin North Am. 2014 Jul;58(3):597-626. [DOI:10.1016/j.cden.2014.04.001] [PMID]
11. Mediavilla Guzmán A, Riad Deglow E, Zubizarreta-Macho Á, Agustín-Panadero R, Hernández Montero S. Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study. J Clin Med. 2019 Dec 2;8(12):2123. [DOI:10.3390/jcm8122123] [PMID] [PMCID]
12. Rawtiya M, Verma K, Sethi P, Loomba K. Application of Robotics in Dentistry Quick Response Code. Indian J Dent Adv. 2014;6:1700-6.
13. Sun TM, Lee HE, Lan TH. The influence of dental experience on a dental implant navigation system. BMC Oral Health. 2019 Oct 17;19(1):222. [DOI:10.1186/s12903-019-0914-2] [PMID] [PMCID]
14. Syed AA, Soomro AM, Khizar AN, Duan X, Qiang H, Manzoor F. Tele-Robotic Assisted Dental Implant Surgery with Virtual Force Feedback. Indones J Electrical Eng Comput Sci. 2014;12(1):450-8. [DOI:10.11591/telkomnika.v12i1.3124]
15. Tan PLB, Layton DM, Wise SL. In vitro comparison of guided versus freehand implant placement: use of a new combined TRIOS surface scanning, Implant Studio, CBCT, and stereolithographic virtually planned and guided technique. Int J Comput Dent. 2018;21(2):87-95.
16. Ganz SD. Three-dimensional imaging and guided surgery for dental implants. Dent Clin North Am. 2015 Apr;59(2):265-90. [DOI:10.1016/j.cden.2014.11.001] [PMID]
17. Casap N, Wexler A, Persky N, Schneider A, Lustmann J. Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system. J Oral Maxillofac Surg. 2004 Sep;62(9 Suppl 2):116-9. [DOI:10.1016/j.joms.2004.06.028] [PMID]
18. Fokas G, Vaughn VM, Scarfe WC, Bornstein MM. Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:393-415. [DOI:10.1111/clr.13142] [PMID]
19. Fortin T, Bosson JL, Coudert JL, Isidori M. Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. Int J Oral Maxillofac Implants. 2003 Nov-Dec;18(6):886-93.
20. Bolding SL, Reebye UN. Robotic-Guided Dental Implant Placement in Fully Edentulous Patients: Preliminary Results of a Prospective Multi-Center Clinical Study. J Oral Maxillofac Surg. 2020;78(10) Supplement:e22-e3. [DOI:10.1016/j.joms.2020.07.064]
21. Naziri E, Schramm A, Wilde F. Accuracy of computer-assisted implant placement with insertion templates. GMS Interdiscip Plast Reconstr Surg DGPW. 2016 May 13;5:Doc15.
22. Kusumoto N, Sohmura T, Yamada S, Wakabayashi K, Nakamura T, Yatani H. Application of virtual reality force feedback haptic device for oral implant surgery. Clin Oral Implants Res. 2006 Dec;17(6):708-13. [DOI:10.1111/j.1600-0501.2006.01218.x] [PMID]
23. DuVall NB. Fabricating a chairside CAD-CAM radiographic and surgical guide for dental implants: A dental technique. J Prosthet Dent. 2021 Jan;125(1):34-40. [DOI:10.1016/j.prosdent.2019.11.019] [PMID]
24. Roig E, Garza LC, Álvarez-Maldonado N, Maia P, Costa S, Roig M, Espona J. In vitro comparison of the accuracy of four intraoral scanners and three conventional impression methods for two neighboring implants. PLoS One. 2020 Feb 27;15(2):e0228266. [DOI:10.1371/journal.pone.0228266] [PMID] [PMCID]
25. Gargallo-Albiol J, Barootchi S, Salomó-Coll O, Wang HL. Advantages and disadvantages of implant navigation surgery. A systematic review. Ann Anat. 2019 Sep;225:1-10. [DOI:10.1016/j.aanat.2019.04.005] [PMID]
26. Vinci R, Manacorda M, Abundo R, Lucchina AG, Scarano A, Crocetta C, et al. Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study. J Clin Med. 2020; 9(3):774. [DOI:10.3390/jcm9030774] [PMID] [PMCID]
27. Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29 Suppl:25-42. [DOI:10.11607/jomi.2014suppl.g1.2] [PMID]
28. Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement. Int J Clin Exp Med. 2015 Jun 15;8(6):8442-9.
29. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res. 2018 Oct;29 Suppl 16:416-35. [DOI:10.1111/clr.13346] [PMID]
30. Kasten B, Arastu A, Panchal N. Dental Implant Surgery: From Conventional to Guided to Navigated Approach. Current Oral Health Reports. 2018;5(2):140-6. [DOI:10.1007/s40496-018-0182-2]
31. Sun TM, Lee HE, Lan TH. Comparing Accuracy of Implant Installation with a Navigation System (NS), a Laboratory Guide (LG), NS with LG, and Freehand Drilling. Int J Environ Res Public Health. 2020;17(6):2107. [DOI:10.3390/ijerph17062107] [PMID] [PMCID]
32. Kaewsiri D, Panmekiate S, Subbalekha K, Mattheos N, Pimkhaokham A. The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial. Clin Oral Implants Res. 2019 Jun;30(6):505- [DOI:10.1111/clr.13435] [PMID]
34. Vercruyssen M, Cox C, Coucke W, Naert I, Jacobs R, Quirynen M. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. J Clin Periodontol. 2014 Jul;41(7):717-23. [DOI:10.1111/jcpe.12231] [PMID]
35. Sreelekshmi S, Varghese K, Abraham JP, Jaysa JJ. Applications Of Robotics In Prosthodontics: A Review. 2017:7(1):198748-198748.
36. Rao YVD, Parimi AM, Rahul DSP, Patel D, Nitin Mythreya YV. Robotics in Dental Implantation. Materials Today: Proceedings. 2017;4(8):9327-32. [DOI:10.1016/j.matpr.2017.07.292]
37. Tahir AM, Jilich M, Trinh DC, Cannata G, Barberis F, Zoppi M. Architecture and design of a robotic mastication simulator for interactive load testing of dental implants and the mandible. J Prosthet Dent. 2019;122(4):389.e1-e8. [DOI:10.1016/j.prosdent.2019.06.023] [PMID]
38. Rawal S, Tillery DE Jr, Brewer P. Robotic-Assisted Prosthetically Driven Planning and Immediate Placement of a Dental Implant. Compend Contin Educ Dent. 2020 Jan;41(1):26-30.
39. Bover-Ramos F, Viña-Almunia J, Cervera-Ballester J, Peñarrocha-Diago M, García-Mira B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int J Oral Maxillofac Implants. 2018 January/February;33(1):101-15. [DOI:10.11607/jomi.5556] [PMID]
40. Laederach V, Mukaddam K, Payer M, Filippi A, Kühl S. Deviations of different systems for guided implant surgery. Clin Oral Implants Res. 2017;28(9):1147-51. [DOI:10.1111/clr.12930] [PMID]
41. Sigcho López DA, García I, Da Silva Salomao G, Cruz Laganá D. Potential Deviation Factors Affecting Stereolithographic Surgical Guides: A Systematic Review. Implant Dent. 2019 Feb;28(1):68-73. [DOI:10.1097/ID.0000000000000853] [PMID]
42. Mello CC, Lemos CAA, de Luna Gomes JM, Verri FR, Pellizzer EP. CAD/CAM vs Conventional Technique for Fabrication of Implant-Supported Frameworks: A Systematic Review and Meta-analysis of In Vitro Studies. Int J Prosthodont. 2019 Mar/Apr;32(2):182-92. [DOI:10.11607/ijp.5616] [PMID]
43. Joda T, Bragger U, Zitzmann NU. CAD/CAM implant crowns in a digital workflow: Five-year follow-up of a prospective clinical trial. Clin Implant Dent Relat Res. 2019 Feb;21(1):169-74. [DOI:10.1111/cid.12681] [PMID]
44. Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res. 2017 May;28(5):602-12. [DOI:10.1111/clr.12841] [PMID]
45. Ozan O, Turkyilmaz I, Ersoy AE, McGlumphy EA, Rosenstiel SF. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. J Oral Maxillofac Surg. 2009 Feb;67(2):394-401. [DOI:10.1016/j.joms.2008.09.033] [PMID]
46. Tallarico M, Kim YJ, Cocchi F, Martinolli M, Meloni SM. Accuracy of newly developed sleeve-designed templates for insertion of dental implants: A prospective multicenters clinical trial. Clin Implant Dent Relat Res. 2019 Feb;21(1):108-113.. [DOI:10.1111/cid.12704] [PMID]
47. Sigcho López DA, García I, Da Silva Salomao G, Cruz Laganá D. Potential Deviation Factors Affecting Stereolithographic Surgical Guides: A Systematic Review. Implant Dent. 2019 Feb;28(1):68-73. [DOI:10.1097/ID.0000000000000853] [PMID]
48. Schubert O, Schweiger J, Stimmelmayr M, Nold E, Güth JF. Digital implant planning and guided implant surgery - workflow and reliability. Br Dent J. 2019 Jan 25;226(2):101-8. [DOI:10.1038/sj.bdj.2019.44] [PMID]
49. Skjerven H, Riis UH, Herlofsson BB, Ellingsen JE. In Vivo Accuracy of Implant Placement Using a Full Digital Planning Modality and Stereolithographic Guides. Int J Oral Maxillofac Implants. 2019 Jan/Feb;34(1):124-32. [DOI:10.11607/jomi.6939] [PMID]
50. Henprasert P, Dawson DV, El-Kerdani T, Song X, Couso-Queiruga E, Holloway JA. Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques. J Prosthodont. 2020 Jul;29(6):534-1. [DOI:10.1111/jopr.13161] [PMID]
51. Chen CK, Yuh DY, Huang RY, Fu E, Tsai CF, Chiang CY. Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling. Int J Oral Maxillofac Implants. 2018 Nov/Dec;33(6):1213-8. [DOI:10.11607/jomi.6585] [PMID]
52. Kiatkroekkrai P, Takolpuckdee C, Subbalekha K, Mattheos N, Pimkhaokham A. Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial. Int J Oral Maxillofac Surg. 2020 Mar;49(3):377-83. [DOI:10.1016/j.ijom.2019.08.019] [PMID]
53. Siessegger M, Schneider BT, Mischkowski RA, Lazar F, Krug B, Klesper B, Zöller JE. Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. J Craniomaxillofac Surg. 2001 Oct;29(5):276-81. [DOI:10.1054/jcms.2001.0242] [PMID]
54. Bell CK, Sahl EF, Kim YJ, Rice DD. Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed. Int J Periodontics Restorative Dent. 2018 Jan/Feb;38(1):113-9. [DOI:10.11607/prd.3254] [PMID]
55. Lee DH, Mai HN, Li LJ, Lee KW. Accuracy of a CAD/CAM-guided template for locating abutment screws for cement-retained implant-supported restorations. J Prosthet Dent. 2016 Jul;116(1):67-73. [DOI:10.1016/j.prosdent.2015.12.007] [PMID]
56. Ma B, Park T, Chun I, Yun K. The accuracy of a 3D printing surgical guide determined by CBCT and model analysis. J Adv Prosthodont. 2018 Aug;10(4):279-85. [DOI:10.4047/jap.2018.10.4.279] [PMID] [PMCID]
57. Zaruba M, Mehl A. Chairside systems: a current review. Int J Comput Dent. 2017;20(2):123-49.
58. Rungcharassaeng K, Caruso JM, Kan JY, Schutyser F, Boumans T. Accuracy of computer-guided surgery: A comparison of operator experience. J Prosthet Dent. 2015 Sep;114(3):407-13. [DOI:10.1016/j.prosdent.2015.04.004] [PMID] [PMCID]
59. Pellegrino G, Bellini P, Cavallini PF, Ferri A, Zacchino A, Taraschi V, et al. Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study. Int J Environ Res Public Health. 2020;17(6):2153. [DOI:10.3390/ijerph17062153] [PMID] [PMCID]
60. Dehghani M, Montazer lotf elahi H, Moeini M, Bardal R. Comparing the Accuracy of Cone Beam Computed Tomography, Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects. J Res Dent Maxillofac Sci. 2016;1(1):34-39. [DOI:10.29252/jrdms.1.1.34]

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Research in Dental and Maxillofacial Sciences

Designed & Developed by: Yektaweb