دوره 11، شماره 2 - ( 4-1405 )                   جلد 11 شماره 2 صفحات 155-148 | برگشت به فهرست نسخه ها

Ethics code: IR.IAU.DENTAL.REC.1403.088

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khodabandehlou F, Zahedi Rad S, Alamdari Mahd M. Spectrophotometric Comparison of Color Change of White Spot Lesions after the Application of Two Types of Resin Infiltrants: An In Vitro Study. J Res Dent Maxillofac Sci 2026; 11 (2) :148-155
URL: http://jrdms.dentaliau.ac.ir/article-1-1330-fa.html
Spectrophotometric Comparison of Color Change of White Spot Lesions after the Application of Two Types of Resin Infiltrants: An In Vitro Study. . 1405; 11 (2) :148-155

URL: http://jrdms.dentaliau.ac.ir/article-1-1330-fa.html


چکیده:   (13 مشاهده)
Background and Aim: This study aimed to spectrophotometrically compare the color change (ΔE) of white spot lesions (WSLs) after the application of ICON and Cobalt resin infiltrants.   
Materials and Methods: In this in vitro study, WSLs were artificially induced in 20 extracted sound human premolars by their 7-day immersion in a demineralizing solution with a pH of 4.4. The specimens were randomly assigned to two groups (n=10) for resin infiltration treatment with ICON and Cobalt resin infiltrants. The color parameters of the specimens were measured before the intervention (T0), after demineralization (T1), immediately after treatment (T2), and 4 weeks after treatment (T3) spectrophotometrically by using the CIEL*a*b* system. ΔE values were calculated and analyzed by independent t-test (alpha=0.05).   
Results: In comparison of ΔE2-0, the difference was not statistically significant between ICON and Cobalt (P=0.234). In comparison of ΔE2-1, ICON (ΔE=12.78) showed a significantly better coverage than Cobalt (ΔE=7.25) (P=0.004). In comparison of ΔE3-2, ICON (ΔE =4.79) showed higher color stability than Cobalt (ΔE=5.24), but the difference was not significant (P=0.667).
Conclusion: The results of this study showed that both ICON and Cobalt effectively corrected the color of WSLs to match the color of sound enamel, although ICON showed a slightly superior performance. The two resin infiltrants also had a comparable color stability after 4 weeks.
 
متن کامل [PDF 391 kb]   (9 دریافت)    
نوع مطالعه: Original article | موضوع مقاله: pediatric

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.