دوره 11، شماره 2 - ( 4-1405 )                   جلد 11 شماره 2 صفحات 173-164 | برگشت به فهرست نسخه ها

Ethics code: IR.IAU.DENTAL.REC.1403.026

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ebrahimgol S, Nemati Anaraki S, Ghanaat M, Ramouz E, Hoorizad ganjkar M. Effect of a Hemostatic Agent on Bond Strength and Durability of Bonding in Three Different Adhesive Systems. J Res Dent Maxillofac Sci 2026; 11 (2) :164-173
URL: http://jrdms.dentaliau.ac.ir/article-1-1226-fa.html
Effect of a Hemostatic Agent on Bond Strength and Durability of Bonding in Three Different Adhesive Systems. . 1405; 11 (2) :164-173

URL: http://jrdms.dentaliau.ac.ir/article-1-1226-fa.html


چکیده:   (7 مشاهده)
Background and Aim: Hemostatic agents may affect the hybrid layer quality. This study evaluated the effect of a hemostatic agent on microtensile bond strength (μTBS) and bonding durability in three adhesive systems.   
Materials and Methods: In this in vitro study, 120 extracted human molars were randomly divided into two main groups (n=60) based on aging conditions: (I) 24-hour storage in distilled water and (II) thermocycling (10,000 cycles, 5°C-55°C). Each group was further subdivided into 6 subgroups (n=10) according to the use of Viscostat Clear and the adhesive system: Adper Single Bond, Clearfil SE Bond, and All-Bond Universal. Composite resin (Filtek Z250) was applied, and μTBS was measured with a testing machine. Failure modes were observed under an optical microscope, and resin-dentin interface was examined by scanning electron microscopy (SEM). Data were analyzed using three-way fixed-effects ANOVA and Tukey’s post-hoc test (α=0.05).   
Results: The highest μTBS was found in the Adper Single Bond group without hemostatic agent after 24 hours of storage (17.37±5.43 MPa), and the lowest was in the All-Bond Universal group with hemostatic agent after thermocycling (5.44±1.21 MPa). At 24 hours, no significant difference existed between contaminated and uncontaminated groups (P>0.05). After thermocycling, Adper Single Bond showed a significant reduction in bond strength when exposed to Viscostat Clear (P=0.000). Adhesive failure predominated in all groups.
Conclusion: The adhesive type and aging process significantly affected the μTBS. While Viscostat Clear did not significantly affect the 24-hour μTBS, it reduced bonding durability after thermocycling in Adper Single Bond group.
 
متن کامل [PDF 759 kb]   (3 دریافت)    
نوع مطالعه: Original article | موضوع مقاله: Restorative Dentistry

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.