دوره 6، شماره 2 - ( 1-1400 )                   جلد 6 شماره 2 صفحات 21-14 | برگشت به فهرست نسخه ها

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farnoosh F, Ansari Lari H, Fatemi M. Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials. J Res Dent Maxillofac Sci 2021; 6 (2) :14-21
URL: http://jrdms.dentaliau.ac.ir/article-1-300-fa.html
Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials. . 1400; 6 (2) :14-21

URL: http://jrdms.dentaliau.ac.ir/article-1-300-fa.html


چکیده:   (2079 مشاهده)

Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability. 
Materials and Methods: In this in-vitro experimental study, dimensional changes of two types of alginate were investigated indirectly by measuring a type III stone cast. Ninety molds of each alginate were obtained from a metal model and stored at 1±4, 1±25, and 1±40°C. The casting was performed 12 minutes, 1 hour, and 4 hours after impression taking. The molds were incubated with an approximate humidity of 100%. The diameter, width, and height of the gypsum casts were measured by a digital caliper with an accuracy of 0.01 mm. Dimensional changes of two alginates in three separate directions were statistically analyzed by three-way analysis of variance (ANOVA) and post-hoc test due to the significant difference.
Results: There was no statistically significant difference in width changes at different temperatures, but regarding the diameter, there was a significant difference between 40°C Chromogel and 25°C Hygedent. Regarding the height, only 40°C Hygedent showed a significant difference at 4 hours compared to 12 minutes (P=0.000, 0.26, and 0.000, respectively). However, no statistically significant difference was observed in other temperatures and times (P>0.05). In most groups, dimensional changes of all samples were not within the clinical standard range (1%).
Conclusion: It seems that the dimensional stability of Hygedent and Chromogel alginates is affected by storage temperature, pouring time, and type of alginate.

متن کامل [PDF 436 kb]   (1378 دریافت)    
موضوع مقاله: Dental implant

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Journal of Research in Dental and Maxillofacial Sciences

Designed & Developed by : Yektaweb