<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Research in Dental and Maxillofacial Sciences</title>
<title_fa></title_fa>
<short_title>J Res Dent Maxillofac Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrdms.dentaliau.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-4166</journal_id_issn>
<journal_id_issn_online>2383-2754</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jrdms</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Effect of One- and Two-Step Processing Techniques on Flexural Strength of Denture Base Acrylic Resin in Dry and Wet Conditions</title>
	<subject_fa>Prosthodontics</subject_fa>
	<subject>Prosthodontics</subject>
	<content_type_fa>Original article</content_type_fa>
	<content_type>Original article</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div&gt;
&lt;table align=&quot;center&quot; hspace=&quot;0&quot; vspace=&quot;0&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;padding: 0cm 12px; text-align: justify;&quot; valign=&quot;top&quot;&gt;&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Background and Aim&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;This study compared the flexural strength (FS) of heat-cure acrylic resin following one- and two-step processing techniques in dry and wet conditions&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;. &amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt; In this in vitro study, 60 acrylic specimens (3&amp;times;10&amp;times;65 mm) were fabricated (ISO20795-1) and flasked using a type III dental stone. The specimens were heated to 70&amp;deg;C for one hour and baked for 30 minutes at 100&amp;deg;C. After cooling and polishing, 30 specimens were randomly selected; of which, 15 were stored in 37&amp;deg;C water, and 15 in dry condition for one month. The remaining 30 were flasked again, baked, and divided into two subgroups for storage in dry and wet conditions. The FS of specimens was measured by a universal testing machine. Data were analyzed by one-way ANOVA and Tukey&amp;#39;s post-hoc test (&amp;alpha;=0.05).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Results: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;The mean FS was 57.5&amp;plusmn;4.8 MPa and 61.7&amp;plusmn;4 &lt;a name=&quot;_Hlk114138066&quot;&gt;MPa&lt;/a&gt; for specimens subjected to one-step processing and stored in wet and dry conditions, respectively. These values were 56.6&amp;plusmn;4 MPa and 64.7&amp;plusmn;2.9 MPa for specimens subjected to two-step processing and stored in wet and dry conditions, respectively (P&lt;0.05). The difference in FS of specimens stored in dry and wet conditions was significant (P&lt;0.05). &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;The two-step processing technique increased the FS while water storage decreased the FS of acrylic resin. FS of specimens subjected to one-step processing with water storage was slightly higher than that of specimens subjected to two-step processing with water storage. FS experienced a greater reduction following two-step processing in a wet environment compared with one-step processing&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;. &amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;
&lt;/div&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Acrylic Resins, Flexural Strength, Polymethyl 
Methacrylate</keyword>
	<start_page>171</start_page>
	<end_page>178</end_page>
	<web_url>http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-1097-2&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sarira</first_name>
	<middle_name></middle_name>
	<last_name>Mehraban Jahromi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sariramehraban@yahoo.com</email>
	<code>100319475328460012006</code>
	<orcid>0000000240474396</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad </first_name>
	<middle_name></middle_name>
	<last_name>Alidad Naeeni</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Mohammadalidadnaeeni@gmail.com</email>
	<code>100319475328460012007</code>
	<orcid>0000000279280185</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Dentistry, Tehran Medical Science, Islamic Azad University,  Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Reza</first_name>
	<middle_name></middle_name>
	<last_name>Mostafa Pour</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rezamost68@yahoo.com</email>
	<code>100319475328460012008</code>
	<orcid>0000000175856389</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Prosthodontics, Faculty of Dentistry, Shahid Beheshti  University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Reza</first_name>
	<middle_name></middle_name>
	<last_name>Nahidi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>r.naidi@iautmu.ac.ir</email>
	<code>100319475328460012009</code>
	<orcid>0000000302195668</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Kaboudanian Ardestani</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alikaboudanian@gmail.com</email>
	<code>100319475328460012010</code>
	<orcid>0000000316625665</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Prosthodontics, Faculty of Dentistry, Tehran Medical Science Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
