<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Research in Dental and Maxillofacial Sciences</title>
<title_fa></title_fa>
<short_title>J Res Dent Maxillofac Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrdms.dentaliau.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-4166</journal_id_issn>
<journal_id_issn_online>2383-2754</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jrdms</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>8</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Effect of Horizontal Cantilever on Microgap and 
Microleakage Through the Implant-Straight 
Abutment Interface in Cement-Retained Crowns</title>
	<subject_fa>Prosthodontics</subject_fa>
	<subject>Prosthodontics</subject>
	<content_type_fa>Original article</content_type_fa>
	<content_type>Original article</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div&gt;
&lt;table align=&quot;center&quot; hspace=&quot;0&quot; vspace=&quot;0&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;padding: 0cm 12px; text-align: justify;&quot; valign=&quot;top&quot;&gt;&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Background and Aim&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;This study aimed to assess the effect of horizontal cantilever on microgap and microleakage at the implant-straight abutment interface in cement-retained crowns. &amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;In this experimental study,&lt;b&gt; &lt;/b&gt;12 implant-abutment assemblies and 12 cement-retained crowns were evaluated. The implant fixtures were bone-level, and had 10 mm length and 4 mm diameter. Straight titanium abutments had 7 mm length, 4 mm diameter, and 1 mm gingival height with Morse-Taper connection. Two groups were evaluated: 6 cement-retained crowns with a horizontal cantilever (test group) and 6 cement-retained crows without a horizontal cantilever (case group). The assemblies underwent load cycling in a chewing simulator. Cyclic load (75 N) with 1 Hz frequency was applied along the longitudinal axis of each specimen to the triangular ridge between the mesiobuccal and mesiolingual cusps of the crown. The amount of microgap before and after cyclic loading, and the microleakage score after immersion in fuchsine were evaluated under a light microscope.&amp;nbsp; Data were compared by t-test (alpha=0.05).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;The change in microgap after cyclic loading compared with before was not significant in the control group (P=0.724). However, in the case group, the amount of microgap significantly increased after cyclic loading compared with before (P=0.000). Microleakage in the case group was significantly greater than that in the control group (P=0.019).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
			&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;Horizontal cantilever caused horizontal microgap and increased the microleakage at the implant-straight abutment interface. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;
&lt;/div&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Dental Implants, Single-Tooth, Dental Implant-Abutment Design, Dental Leakage</keyword>
	<start_page>162</start_page>
	<end_page>170</end_page>
	<web_url>http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-823-2&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Arezu</first_name>
	<middle_name></middle_name>
	<last_name>Babasafari</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>arezu.b.ab@gmail.com</email>
	<code>100319475328460012000</code>
	<orcid>0000000254804886</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Prosthodontics,  Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Ezatollah</first_name>
	<middle_name></middle_name>
	<last_name>Jalalian</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dr_e_jalalian@gmail.com</email>
	<code>100319475328460012001</code>
	<orcid>0000000259378687</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Fixed Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Arash</first_name>
	<middle_name></middle_name>
	<last_name>Zarbakhsh</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>arashz1350@gmail.com</email>
	<code>100319475328460012002</code>
	<orcid>0000000182718697</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Fixed Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Abdolkarim</first_name>
	<middle_name></middle_name>
	<last_name>Rostamian</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>abdolkarim.rostamian@gmail.com</email>
	<code>100319475328460012003</code>
	<orcid>000000028956494X</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Fixed Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Shaghayegh</first_name>
	<middle_name></middle_name>
	<last_name>Golalipour</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sh.golalipour@gmail.com</email>
	<code>100319475328460012004</code>
	<orcid>0000000197361846</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Fixed Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Sotoudeh</first_name>
	<middle_name></middle_name>
	<last_name>khorshidi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Atenakhorshidi94@gmail.com</email>
	<code>100319475328460012005</code>
	<orcid>0000000203697865</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Fixed Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
