Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA).
Materials and Methods: Four three-dimensional (3D) finite element models were designed by using ANSYS 14.5 software: (1) a straight titanium abutment, (2) a straight zirconia abutment, (3) a 20° angled titanium abutment, and (4) a 20° angled zirconia abutment in the anterior maxilla. Standard Straumann® implants with regular necks (4.8×12 mm) were selected. Premaxillary bone with type 3 bone quality was modelled with a 0.5-mm-thick cortical layer. A 178-N oblique load was applied to the cingulum of the models. Afterwards, stress and strain distributions were measured by using ANSYS 14.5 software.
Results: Maximum stress and strain concentrated at the implant-abutment joint at the cervical one-third of crestal bone, mainly in the labial surface. The abutment's material had a less substantial effect on the distribution of stress and strain compared to the angle of the abutment. Stress and strain concentration in angled abutments was higher than that in straight abutments. However, angled abutments transferred lower levels of stress and strain to the bone compared to straight abutments.
Conclusion: It can be concluded that an angled abutment might decrease the stress and strain in the anterior maxillary bone in comparison with straight abutments.
Full-Text [PDF 369 kb]   (1761 Downloads) |   |   Full-Text (HTML)  (774 Views)  
Type of Study: Original article | Subject: Dental implant

References
1. Cavallaro J Jr, Greenstein G. Angled implant abutments: a practical application of available knowledge. J Am Dent Assoc. 2011 Feb;142(2):150-8.
2. Saab XE, Griggs JA, Powers JM, Engelmeier RL. Effect of abutment angulation on the strain on the bone around an implant in the anterior maxilla: A finite element study. J Prosthet Dent. 2007 Feb;97(2):85-92.
3. Levin BP, Rubinstein S, Rose LF. Advanced aesthetics management of dental implants: surgical and restorative considerations to improve outcomes. J Esthet Restor Dent. 2015 Jul-Aug;27(4):224-30.
4. Papavasiliou G, Kamposiora P, Bayne SC, Fellton DA. Three dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent. 1996 Dec;76(6):633-40.
5. Sethi A, Kaus T, Sochor P. The use of angulated abutments in implant dentistry: five-year clinical results of an ongoing prospective study. Int J Oral Maxillofac Implants. 2000 Nov-Dec;15(6):801-10.
6. Arun Kumar G, Mahesh B, George D. Three dimensional finite element analysis of stress distribution around implant with straight and angled abutments in different bone qualities. J Indian Prosthodont Soc. 2013 Dec;13(4):466–72.
7. Hasan I, Roger B, Heinemann F, Keilig L, Bourauel C. Influence of abutment design on the success of immediately loaded dental implants: experimental and numerical studies. Med Eng Phys. 2012 Sep;34(7):817-25.
8. Wu T, Liao W, Dai N, Tang C. Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis. J Biomech. 2010 Jul 20;43(10):1941-6.
9. Tian K, Chen J, Han L, Yang J, Huang W, Wu D. Angled abutments result in increased or decreased stress on surrounding bone of single-unit dental implants: a finite element analysis. Med Eng Phys. 2012 Dec;34(10):1526-31.
10. Kao HC, Gung YW, Chung TF, Hsu ML.The influence of abutment angulation on micromotion level for immediately loaded dental implants: A 3-D Finite element Analysis. Int J Oral Maxillofac Implants. 2008 Jul-Aug;23(4):623-30.
11. Canay S, Hersek N, Akpinar I, Asik Z. Comparison of stress distribution around vertical and angled implants with finite-element analysis. Quintessence Int. 1996 Sep;27(9):591-8.
12. Geramy A, Morgano SM. Finite element analysis of three designs of an implant-supported molar crown. J Prosthet Dent. 2004 Nov;92(5):434-40.
13. Hellsing G. On the regulation of interincisor bite force in man. J Oral Rehabil. 1980 Sep;7(5):403-11.
14. Helkimo E, Carlsson GE, Helkimo M. Bite force and state of dentition. Acta Odontol Scand. 1977;35(6):297-303.
15. Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001 Jun;85(6):585-98.
16. Clelland NL, Lee JK, Bimbenet OC, Brantley WA. A three- dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J Prosthodont. 1995 Jun;4(2):95-100.
17. Hasan I, Bourauel C, Keilig L, Reimann S, Heinemann F. The influence of implant number and abutment design on the biomechanical behaviour of bone for an implant-supported fixed prosthesis: a finite element study in the upper anterior region.Comput Methods Biomech Biomed Engin. 2011 Dec;14(12):1113-6.
18. Jafari k, Vojdani M, Mahdavi F, Heidary H. Finite element analysis of the effect of superstructure materials and loading angle on stress distribution around the implant. J Dent Biomater. 2014;1(2):57-62.
19. Sadrimanesh R, Siadat H, Sadr-Eshkevari P, Monzavi A, Maurer P, Rashad A. Alveolar bone stress around implants with different abutment angulation: an FE-analysis of anterior maxilla. Implant Dent. 2012 Jun;21(3):196-201.
20. Bahuguna R, Anand B, Kumar D, Aeran H, Anand V, Gulati M. Evaluation of stress patterns in bone around dental implant for different abutment angulations under axial and oblique loading. A finite element analysis. Natl J Maxillofac Surg. 2013 Jan;4(1):46-51.
21. Wu D, Tian K, Chen J, Jin H, Huang W, Liu Y.A further finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. Comput Math Methods Med.2015;2015:560645.
22. Danza M, Palmieri A, Farinella F, Brunelli G, Carinci F, Girardi A, et al. Three dimensional finite element analysis to detect stress distribution in spiral implants and surrounding bone. Dent Res J (Isfahan). 2009 Fall;6(2):59-64.
23. Cardelli P, Montani M, Gallio M, Biancolini M, Brutti C, Barlattani A. Angulated abutments and periimplants stress: F.E.M. Analysis. Oral Implantol (Rome). 2009 Jan;2(1):3-10.
24. Geng JP, Xu DW, Tan KB, Liu GR. Finite element analysis of an osseointegrated stepped screw dental implan. J Oral Implantol. 2004;30(4):223-33.
25. Las Casas EB, Ferreira PC, Cimini CA Jr, Toledo EM, Barra LP, Cruz M. Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs. Int J Oral Maxillofac Implants. 2008 Mar-Apr;23(2):215-25.
26. Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol. 1997;23(3):104-11.
27. Weinberg LA. Reduction of implant loading with therapeutic biomechanics. Implant Dent. 1998;7(4):277-85.
28. O`Mahony A, Williams JL, Spencer P. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increase peri-implant stress and strain under oblique loading. Clin Oral Implants Res. 2001 Dec;12(6):648-57.
29. Frost HM. Bone "mass" and the "mechanostat": a proposal. Anat Rec. 1987 Sep;219(1):1-9.
30. Ismail YH, Pahountis LN, Fleming JF. Comparison of two-dimensional and three dimensional finite element analysis of a blade implan. Int J Oral Implantol.1987;4(2):25-31.
31. Ebadian B, Mosharraf R, Abbasi S, Memar Ardestani P, Farzin M.The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis.Eur J Dent. 2015 Jul-Sep;9(3):311–8.
32. Solberg k, Heinemann F, Pellikaan P, Keilig L, Stark H, Bourauel C,et al. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants.Computer Methods Biomech Engin 2017 May;20(7):770-82.
33. Moon SY, Lim YJ, Kim MJ, Kwon HB. Three-dimensional finite element analysis of platform switched implant. J Adv Prosthodont. 2017 Feb;9(1):31–7.

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.