<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Research in Dental and Maxillofacial Sciences</title>
<title_fa></title_fa>
<short_title>J Res Dent Maxillofac Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jrdms.dentaliau.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-4166</journal_id_issn>
<journal_id_issn_online>2383-2754</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/jrdms</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1405</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2026</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Effect of Polishing and Glazing on Microhardness of Monolithic Zirconia, Lithium Disilicate, and Zirconia-Reinforced Lithium Silicate CAD/CAM Ceramics: An In Vitro Study</title>
	<subject_fa>Restorative Dentistry</subject_fa>
	<subject>Restorative Dentistry</subject>
	<content_type_fa>Original article</content_type_fa>
	<content_type>Original article</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Background and Aim&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt; This study aimed to assess the effect of polishing and glazing on microhardness of monolithic zirconia, lithium disilicate (LDS), and zirconia-reinforced lithium silicate (ZLS) computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics. &amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt; In this in vitro study, square-shaped specimens (10 x 10 x 1 mm) were fabricated from Suprinity, IPS e.max CAD, and Incoris ZI ceramics (n=24 from each). Each group was subdivided into three subgroups (n=8) for (I) glazing, (II) polishing with Diapol Twist kit, and (III) no surface treatment (control). Microhardness was assessed using Vickers hardness tester. Comparisons were made with two-way ANOVA and Tukey&amp;rsquo;s test (alpha=0.05). &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt; &lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;Ceramic type had a significant effect on microhardness (P&lt;0.001) such that Incoris ZI showed the highest, and IPS e.max CAD showed the lowest microhardness (P&lt;0.05). The effect of surface treatment on microhardness was also significant (P&lt;0.001) such that the control group showed the highest and the polishing group showed the lowest microhardness (P&lt;0.05). The interaction effect of ceramic type and surface treatment on microhardness was not significant (P=0.454).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:13pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt;&lt;span style=&quot;color:#2e74b5&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:97%&quot;&gt;&lt;span style=&quot;font-family:&quot; verdana=&quot;&quot;&gt; Within the study limitations, the findings showed that the microhardness values differed significantly across groups, and the control group had a higher microhardness than the polishing and glazing groups. The values tended to be higher for Incoris ZI ceramic, indicating that this ceramic may demonstrate greater wear resistance in clinical situations.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Computer-Aided Design, Dental Polishing, Hardness, Yttria stabilized tetragonal zirconia</keyword>
	<start_page>251</start_page>
	<end_page>258</end_page>
	<web_url>http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-369-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sayyed Mohammad-Reza</first_name>
	<middle_name></middle_name>
	<last_name>Ghelmani</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460017643</code>
	<orcid>100319475328460017643</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Prosthodontics, TeMS.C., Islamic Azad University, Tehran, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Reza</first_name>
	<middle_name></middle_name>
	<last_name>Nahidi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rezanahidi@gmail.com</email>
	<code>100319475328460017644</code>
	<orcid>100319475328460017644</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Prosthodontics, TeMS.C., Islamic Azad University, Tehran, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Arash</first_name>
	<middle_name></middle_name>
	<last_name>Zarbakhsh</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Arashz1350@gmail.com</email>
	<code>100319475328460017645</code>
	<orcid>100319475328460017645</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Prosthodontics, TeMS.C., Islamic Azad University, Tehran, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
